You can spend months choosing kitchen worktops and about nine minutes thinking about where the internet comes from. That is usually the wrong way round. In a UK renovation, the cables that disappear behind plasterboard are the hardest things to change later. The socket you skipped in the hallway becomes the reason the video doorbell drops out. The missing ceiling point turns a neat access point into a plastic box on a shelf.

This is not a pitch for cable everywhere. It is a pitch for deciding now, while the walls are open and the electrician is already on site. Below is a room-by-room checklist you can print, annotate and hand over. Treat it as a brief, not a final design.

Start with a comms cupboard, not a socket count

Before room lists, choose where the messy stuff lives. A small wall-mounted cabinet in a hallway, under-stairs space or garage is better than a shelf in the living room. It needs power, ventilation, and enough depth for a router, ONT, switch and maybe a small NAS. Ask for a double socket inside, not a single socket nearby.

From there, run star-shaped cabling to each room. Avoid daisy chains. Use Cat6a if the budget allows; it is not much harder to terminate and gives you headroom. Leave pull cords in conduit to awkward spots. Label both ends.

Room-by-room data points

Hallway and entrance. One data point for the doorbell or intercom, one for a ceiling access point if the hallway is long, and one near the front door for a smart hub or keypad. If you have a porch, consider a cable to the porch ceiling for a camera or doorbell.

Living room. Two to four data points behind the TV, not one. Think TV, streaming box, games console, and a spare. Add one on the opposite wall for a desk or Wi-Fi point. Coax is optional; most TV now arrives over broadband, but a conduit to the TV wall is cheap insurance.

Kitchen. One data point for a smart display or under-cabinet tablet, one for a ceiling access point if the kitchen is a Wi-Fi dead zone, and one near the utility area for a printer or smart hub. Avoid putting the main router here; steam and clutter are not friends.

Bedrooms. At least one data point per bedroom, ideally two: one at a desk, one behind a TV. Add a ceiling point in the landing if bedrooms struggle. Do not forget the loft if you plan a future access point or CCTV recorder.

Home office. Two data points minimum: desk and printer. A third for a backup connection or a small switch. If you run a business from home, treat it like a small office: wired where possible, Wi-Fi for phones and guests.

Bathrooms and cloakrooms. Probably no data point, but think about a ceiling access point outside the door if the walls are thick. Avoid sockets in wet zones; let the electrician advise.

Ceiling access points and the Wi-Fi myth

A single router in the hallway is not a plan for a Victorian terrace with a rear extension. Ceiling access points wired back to the comms cupboard give better coverage and look neater than mesh boxes on sideboards. Ask for Cat6a to ceiling positions in the hallway, landing, kitchen and any large open-plan space. Mark the exact spots before first-fix; a ceiling point 30cm from where you want it is still wrong.

If you are not ready for access points, fit the cable and leave it coiled behind a blank plate. Future you will be grateful.

Doorbells, cameras and outdoor kit

Video doorbells are usually Wi-Fi, but a wired power feed or PoE point is more reliable than battery swapping. For cameras, PoE is the quiet winner: one cable for power and data, no local power supply. Run cable to soffits and gate posts before landscaping. If you have a driveway, think about a duct under it, not a cable laid on top.

Garden office and outbuildings

A garden office needs a data link, not just Wi-Fi from the kitchen. Run Cat6a in a duct from the house to the office, with a draw wire. If the run is over 80 metres, ask about fibre. Add power, surge protection and a small consumer unit if the electrician recommends it. For a garage or workshop, one data point and one ceiling point cover most needs.

Small business premises

The same logic applies to a shop, clinic or studio. Add data points at the till, card terminal, back office, CCTV recorder and staff room. If you have a counter, put a socket where the card machine sits, not where the queue forms. Plan a separate guest Wi-Fi access point. For a small office, a wall cabinet with a patch panel and switch is worth the small extra cost.

What to hand over

Give your electrician a simple schedule: room, position, height, cable type, and what it is for. Mark it on the floor plan. Agree who terminates and tests. Ask for test results and photos before plasterboard goes up. A few labelled cables and a clear plan are worth more than a last-minute scramble.

The rule is simple: if you think you might want a cable in five years, fit conduit now. Plasterboard is forever; regret is optional.

All Articles

Related Articles

When Solid Walls Meet Strong Signals: Wiring a Period Home for the Full-Fibre Era

When Solid Walls Meet Strong Signals: Wiring a Period Home for the Full-Fibre Era

The Quiet Line: Auditing the Legacy Kit That Still Thinks It's on a Phone Line

The Quiet Line: Auditing the Legacy Kit That Still Thinks It's on a Phone Line

Before the Rush: A Connectivity MOT for Independent Shops

Before the Rush: A Connectivity MOT for Independent Shops