An Hour With a Torch: The November Walk-Round for Outdoor Network Kit

Totally Wired Solutions
An Hour With a Torch: The November Walk-Round for Outdoor Network Kit

Photo by Photo by Annie Spratt on Unsplash on Unsplash

Every winter throws up the same faults. The garden office link that drops whenever the temperature falls below about three degrees. The camera that fogs from the inside, so you get a lovely soft-focus view of the driveway and nothing you could identify in a hurry. The UPS that has sat quietly in a cupboard for four years and turns out to last roughly as long as it takes to walk to the front door.

None of these are mysteries. They are all predictable, and nearly all of them are visible in November if you put a coat on, take a torch and spend an hour looking. Treat it like a boiler service: dull, cheap, and considerably better than the phone call you would otherwise be making in January.

Why now, and why a torch

Frost does not break things. Frost reveals things that were already marginal. A cable gland that is 90% sealed lets a trickle in during October, the water sits in the housing, and the first hard freeze expands it. Seals that have gone hard in the sun crack when they are flexed by wind. A lead-acid battery loses a chunk of its capacity in the cold, so a UPS that was already tired gives up without warning.

Pick a dry, still day. Rain makes it impossible to see whether a seal is actually sealing, and wind on a ladder is its own conversation. A torch is essential even in daylight, because most of the interesting failure modes live underneath things, behind things and inside small dark boxes.

Start where the cable comes in

Walk the outside of the building and find every point where a cable enters. Then look up at it.

The external access point

An outdoor AP is a sealed unit with a rubber gasket, a few glands and a PoE feed. That is all it is. They are tough, but they are not immortal.

Look at the housing for hairline cracks, particularly around the mounting screws where someone may have over-tightened it. Check the gasket is still soft and seated, not squashed flat or hanging out at one corner. Look at the Ethernet port: if there is a boot on the connector, pull it back gently and check for green or black corrosion on the pins. That is water, and it has been there a while.

Then check the other end. The PoE injector or switch port indoors should be dry, and the run should show the same link speed it always has. A link that has quietly renegotiated from 1GbE to 100MbE is often a damaged pair, and it will get worse.

If the AP sits under a soffit, clear the leaves and the moss. If it is on a pole in the garden, check the pole is still vertical and the bracket has not started to pull out of soft ground.

Garden office and shed links

If the link to the end of the garden goes through ducting, lift the cover at both ends and have a look inside. Duct that has filled with water and then frozen is a genuinely unpleasant discovery, because the ice can pinch or split the cable.

Check the cable where it leaves the ground. Sharp bends, cable ties cinched tight against a wall and a run that sits in a puddle are all things to fix while the weather is merely grim rather than hostile. If the link is a point-to-point wireless bridge, check the alignment has not shifted and that the mounting has not loosened in the wind.

Cameras and other small outdoor kit

Fogging on the inside of a camera lens means moisture got in, usually through a gland or a failed seal, and it is not going to clear on its own. Wipe the outside of the lens, then look at the image on a screen rather than squinting at the unit. A slightly hazy picture now is a useless picture in February.

Clear cobwebs and trim anything that has grown across the field of view. Check that the IR still switches on at dusk. And if a camera is held on by a bracket that moves when you press it, tighten it before the first gale does the job for you.

Enclosures, boxes and the condensation problem

Any outdoor cabinet or enclosure needs three things: a decent IP rating, a mounting position that keeps it off the worst of the weather, and some way for moisture to leave. A sealed box on a cold wall will collect condensation inside regardless of how good the seal is, particularly where warm air from indoors meets a cold surface.

Look for water pooling in the bottom, rust on screws and terminals, and a musty smell when you open it. Where the manufacturer allows it, a small breather gland or a sachet of desiccant can make a real difference. Do not drill drain holes into an enclosure unless the instructions say so. That is how you turn a damp box into a wet one.

The battery question

This is the one most people skip, and it is the one that matters most. A UPS that protects the router, the ONT and the switch is only useful if the battery inside it still holds charge. Sealed lead-acid batteries, which most small units use, degrade quietly and lose capacity faster in the cold.

Run the self-test if the unit has one. Then do something more honest: pull the mains for two minutes while watching the equipment. If anything reboots, the battery is done. Check the date on the battery label. Anything over three to four years old is on borrowed time, and replacing it in November is a great deal easier than explaining to a customer why the card machine went down in a power cut.

Write it down

Keep a note of what you checked, what you tightened, what looked marginal and which battery will need replacing next autumn. A photograph of each enclosure before you close it is worth more than memory. Next year you will thank yourself, and if anyone else ever has to work on the system, they will thank you too.

What to leave alone

Anything on the mains side, anything at height that needs more than a step ladder, and anything belonging to the network provider. An electrician is cheaper than an afternoon in A&E, and the Openreach box is not yours. Know where your competence ends and stop there.

The whole routine takes about an hour on a typical house and perhaps two on a small commercial site. It will not catch everything, but it catches the majority of the faults that turn into emergency call-outs between December and March. Worth a coat, we think.

All Articles

Related Articles

Heat Rises, Uptime Falls: Moving Always-On Network Kit Out of the Loft

Heat Rises, Uptime Falls: Moving Always-On Network Kit Out of the Loft

The Network Is Part of the Sale Now: Handing Over a Connected Home Without the Headache

The Network Is Part of the Sale Now: Handing Over a Connected Home Without the Headache

Swap the ISP, Keep the Walls: A Broadband-Agnostic Cabling Plan

Swap the ISP, Keep the Walls: A Broadband-Agnostic Cabling Plan